Skip to content

Canopy LED retrofits. NEC 514-compliant. ComEd-filed.

ComEd's per-watt incentive applies to every watt the canopy retrofit removes. We model your station's incentive and payback before anything is quoted.

The wiring path inside the canopy column

Fixtures sit above the hazardous zone; the conduit route through the column does not. That one path triggers the petroleum wiring methods sign shops skip.

Canopy column section with NEC callouts for rigid conduit, sealing, bonding, and disconnect locationLED fixture18 in. classified zone1234
  • Threaded RMC or IMC through the classified zone

    EMT, NM cable, and standard flex do not cross the canopy column path.

    NEC 501.10(A)

  • Seal fittings at every zone boundary

    EYS seals stop vapor migration where the raceway exits the 18-inch classified envelope.

    NEC 514.9 / 501.15

  • Bonding that survives fault conditions

    Bond bushings and listed fittings keep the grounding path intact through every metallic connection.

    NEC 514.16 / 501.30

  • Emergency shutoff in code distance

    One marked disconnect removes power to the classified-area equipment 20 to 100 feet from the dispensers.

    NEC 514.11

A sign shop swaps the fixture and leaves. The conduit path stays untouched — and out of code.

12 fixtures. 3,000 watts reduced. ComEd pays per watt.

ComEd's Standard Offering calculates incentives on watts reduced, not fixtures replaced. Twelve canopy fixtures drop 3,000 watts, and every one of them counts toward the incentive. We calculate the exact figure for your station during the assessment.

Reference model

12 × 400 W metal halide

4,800 W

12 × 150 W LED

1,800 W

63% less per fixture: 250 W saved on each, 3,000 W across all 12.

Fixtures
12 recessed canopy
Run time
12 hr / day
Incentive basis
3,000 W × current ComEd per-watt rate

Incentive stack

Standard Offering
Per-watt base incentive
Select Communities
Location-based bonus
Kickstart
Program bonus when available
Made in Illinois
Product-sourcing bonus

Reservation letter required before installation begins.

Five zones. One filing. One contractor.

The scope can move from canopy to lot, c-store, signage, and wash bay under one lighting filing.

  • Canopy fixtures

    75–200 W, recessed mount, DLC 5.1

  • Lot perimeter

    Full cutoff poles, IES RP-8, dark-sky optics

  • Interior c-store

    LED troffers, case lighting, HB2363-ready

    Illinois HB2363: CFL ban Jan 2026, linear fluorescent ban Jan 2027

  • Brand signage

    Pylon and fascia, coordinated color temperature

  • Car wash bay

    Vapor-tight, wet-rated, IP66

Survey to closeout, without shutting down the site

The sequence is short, documented, and built around keeping the station operational while the incentive path stays intact.

  1. Inventory

    1–2 hr site visit

    Fixture inventory, watt reduction math, and ComEd eligibility confirmed before anything is quoted.

  2. Pre-application

    1–2 weeks

    ComEd reservation filed before installation — the incentive is locked in before the first fixture comes down.

  3. Specification

    1 week

    DLC 5.1 fixtures selected, IES layout calculated for canopy, lot, and store in one design pass.

  4. Install

    1–2 days

    Lighting circuits swapped in 1–2 working days. Pumps stay active.

  5. Closeout

    2–4 weeks

    Post-install light levels verified. Final ComEd documentation filed. Incentive released.

Price the canopy, lot, and store on one assessment.

Fixture inventory. Classified-zone scope review. Watt reduction math. ComEd filing path. All confirmed before installation starts.